2012-10-24

VPSA Oxygen Gas Purifier Maker


Categories: VPSA Oxygen Generators
Brand:RICH
Comments:Capacity:200-5000Nm3/h
Purity: 85%-95%
Energy consumption of equipment: 0.35-0.52Kw/Nm3O2


Capacity:200-5000Nm3/h Purity: 85%-95% Energy consumption of equipment: 0.35-0.52Kw/Nm3O2
1.Compenents of VPSA Oxygen Generater
1.1 Air Fan and Vacuum Pump
Air fan provide air source for the whole system. Based on VPSA oxygen generator design condition and customer requirements, fan with proper outlet air pressure is to be provided. Vacuum pump ensures correct system operation and keeps the system in ideal vacuum state, which ensures equipment constantly adsorb nitrogen and produce oxygen.
1.2 Temperature Regulating System
Air temperature regulating system is made up of a water cooler and an electric heater. The temperature of air compressed by fan is around 65oC-70oC, passing the water cooler, its temperature is reduced to meet the requirements of process operation. Then it is sent into the adsorption towers. In winter, the temperature of air is to be increased by the electric heater and reaches the requirements of process operation.
1.3 Adsorption System
The adsorption system mainly consists of two towers filled with zeolite molecular sieve adsorbents and piping valves etc. Air enters into the bottom of one tower, when passing through the adsorbent layer,N2, Coxygen, Vapor are adsorbed by molecular sieve and oxygen passes through the adsorbents and gathers at the top of tower, flowing out as produced gas, meanwhile the other tower is in the process of regeneration. When the adsorbing tower almost reaches saturation, by the operation of control system, the processing air flows into the regenerated tower and begins to produce oxygen.Two towers alternately adsorb and constantly produce oxygen .
1.4 Oxygen Buffer Tank
Compared with three-tower process, oxygen generator with two towers can not produce consecutive oxygen, therefore, a buffer tank with large volume is needed for stable oxygen output.


2.Technical Index
Oxygen production: 200~5000Nm3/h
Oxygen Purity: 85~95%
Outlet pressure: 0.015~0.05MPa (adjustable)
3. Features
3.1 Quick and convenient start and stop.
3.2 Low investment and energy consumption.
3.3 High automation.
3.4 Simple operation and maintenance.
3.5 Short installation period and small ground treatment workload.


KeyWords:



没有评论: